1926.56 - Illumination

1926.56(a)

General. Construction areas, ramps, runways, corridors, offices, shops, and storage areas shall be lighted to not less than the minimum illumination intensities listed in Table D-3 while any work is in progress:

    TABLE D-3 - MINIMUM ILLUMINATION INTENSITIES IN FOOT-CANDLES

____________________________________________________________________
               |
 Foot-candles  |            Area or operation
_______________|____________________________________________________
               |
5............. | General construction area lighting.
3............. | General construction areas, concrete placement,
               |   excavation and waste areas, access ways, active
               |   storage areas, loading platforms, refueling, and
               |   field maintenance areas.
5............. | Indoors: warehouses, corridors, hallways, and
               |   exitways.
5............. | Tunnels, shafts, and general underground work areas:
               |   (Exception: minimum of 10 foot-candles is required
               |   at tunnel and shaft heading during drilling,
               |   mucking, and scaling. Bureau of Mines approved cap
               |   lights shall be acceptable for use in the tunnel
               |   heading)
10............ | General construction plant and shops (e.g., batch
               |   plants, screening plants, mechanical and
               |   electrical equipment rooms, carpenter shops,
               |   rigging lofts and active store rooms, mess halls,
               |   and indoor toilets and workrooms.)
30............ | First aid stations, infirmaries, and offices.
_______________|____________________________________________________

 